Editing controls
Source and compliance editing
When the Series 2600 is in the edit mode (EDIT annunciator on), the editing
controls are used to set source and compliance values. Note that source auto
ranging will turn off when editing the source value.
Editing source values
1. Press the SRC key to edit the source. Note that the cursor will flash in the
source value field of the display.
2. Place the blinking cursor on the desired digit by using either the CURSOR
keys, or by turning the Rotary Knob.
3. Press in on the Rotary Knob to enter the edit mode, as indicated by the
EDIT annunciator.
4. Modify the source value in either one of two ways:
• Rotate the Rotary Knob to adjust the digit. Note that the digit will
automatically overflow or underflow to the next digit when the maxi
-
mum is reached.
• Directly enter the desired value using the numeric keys (0-9, +/-, 0000).
Note that +/- toggles the polarity, while 0000 sets the value to 0.
5. Once the desired value is displayed, either press ENTER, or press in on
the Rotary Knob to complete editing. Note that the EDIT annunciator goes
off.
6. To cancel source editing without making a change, press the EXIT key
instead of using ENTER or press in on the Rotary Knob.
Editing compliance values
1. For the Model 2601/2611 or the Model 2602/2612 single-channel display
mode, press the LIMIT key to directly edit the compliance value.
2. For the Model 2602/2612 dual-channel display mode, press LIMIT or
CONFIG then LIMIT to edit the compliance limit. Next, select either
VOLTAGE or CURRENT either by using the CURSOR keys or by rotating
the Rotary Knob. Press ENTER or the Rotary Knob.
3. Place the blinking cursor on the desired digit by using either the CURSOR
keys, or by turning the Rotary Knob.
4. Press in on the Rotary Knob to enter the edit mode, as indicated by the
EDIT annunciator.

Table of Contents

Other manuals for Keithley SourceMeter 2612

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley SourceMeter 2612 and is the answer not in the manual?

Keithley SourceMeter 2612 Specifications

General IconGeneral
BrandKeithley
ModelSourceMeter 2612
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals