SERVICE MANUAL
FASTMIG X
27 (37)
Kemppi OY
1.1 Primary rectifier V5
Primary side primary rectifier diodes can be measured one at the time
Diodes must be measured both forward bias and reverse bias condition to make sure they are fine
Check the diodes using the multimeter diode function to measure their threshold voltage 0,3…0,6 V
Measurings:
Positive test lead Negative test lead Result
X1, X2, X3 (one at time) X16 0,3-0,7VDC
X16 X1, X2, X3 (one at time) no value
X20 X1, X2, X3 (one at time) 0,3-0,7VDC
X1, X2, X3 (one at time) X20 no value
X16
X20
X1
X2
X3