EasyManuals Logo

Kemppi MasterTig 235ACDC User Manual

Kemppi MasterTig 235ACDC
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
7. Pulse mode selection button
Selects the pulse mode or turns the pulse off: Auto / Manual / Pulse off
8. Gas test button
Flushes the gas line without ignition and welding
Pressing the Gas test button starts the gas test with default time. Gas test time can be adjusted by turning the con-
trol knob (1) during the gas test:0 s ... 60 s, step 1 s (Default: 20 s)
Gas test can be stopped by pressing the button again.
9. Start & stop sequence button
Toggles between Start & stop sequence settings: Pregas / Upslope / Hot start level / Hot start time / Minilog (4T
only) / Downslope / Postgas
If AC mode is on, AC frequency and AC balance settings can be accessed
If Pulse mode is on, Pulse current, Pulse ratio, Base current and Pulse frequency settings can be accessed
>> In the Pulse Auto mode, these settings can be viewed only.
10. Settings button
Opens the settings menu
Advanced settings can be accessed with a long press of the button.
Settings menu content depends on the currently selected welding process and mode.
11. Home button
Returns you to the initial work mode where the welding current (A) can be adjusted
Lights and symbols:
a. Cooling unit
Green: Cooling unit is connected and running
Red: Cooling unit is connected, but there is a problem (e.g. with coolant circulation)
b. Operating temperature
Yellow: Welding equipment has overheated
c. General notification
Yellow: There is an error that requires attention
Red: There is a fault that prevents welding
The error code is shown on the display. If the error does not prevent welding, this error code can be dismissed, but
the notification light stays lit.
d. VRD (voltage reduction device)
Green:VRD is on
Red (blinking):There is a fault with VRD that prevents welding
Not lit:VRD is off
e. Wireless device
Blue:Wireless device is connected
Blue, blinking:Pairing in progress.
In error situations, an error code is displayed. Refer to "Troubleshooting" on page57 for more information on the
error in question.
For welding process and control panel feature descriptions, refer to "Welding processes and features" on page72.
© Kemppi
28
1920900 / 2052

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi MasterTig 235ACDC and is the answer not in the manual?

Kemppi MasterTig 235ACDC Specifications

General IconGeneral
BrandKemppi
ModelMasterTig 235ACDC
CategoryWelding System
LanguageEnglish

Related product manuals