EasyManuals Logo

Kemppi MasterTig 235ACDC User Manual

Kemppi MasterTig 235ACDC
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
MasterTig 235ACDC, 325DC, 335ACDC, 425DC
Operating manual - EN
* Auto Pulse mode has different parameter values and they cannot be adjusted.
"Welding processes and features" on page72
3.2.3 Settings
The contents of the Settings menu depend on the welding process, current mode and welding mode selected.
To select and adjust parameters in Settings menu:
1. Press the parameter settings button (10) to enter the menu.
2. Browse through the menu parameters by turning the control knob (1).
3. Select a parameter for adjustment by pressing the control knob button (1).
4. Adjust the selected parameter by turning the control knob (1).
5. Close the parameter setting by pressing the control knob button (1).
To enter advanced Settings menu:
Press the Settings button (10) for 5 seconds.
Rarely used settings items are hidden by default. Those are available in the advanced settings menu.
Settings:
Parameter Value Note
Latest weld
Current, voltage, arc time This settings item shows last weld data values.
AC Waveform
Sine / Optima / Square (Default: Optima)
Spot time
0.1 s ... 150.0 s, step 0.1 / 1.0 s (Default = 2.0 s)
© Kemppi
32
1920900 / 2052

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi MasterTig 235ACDC and is the answer not in the manual?

Kemppi MasterTig 235ACDC Specifications

General IconGeneral
BrandKemppi
ModelMasterTig 235ACDC
CategoryWelding System
LanguageEnglish

Related product manuals