EasyManuals Logo

Kemppi MinarcTig Evo 200 Service Manual

Kemppi MinarcTig Evo 200
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Service manual MinarcTig Evo 200
Version 1.1.5.
29.9.2015
14
Kemppi Oy
3.4.6. Error codes
Error code
Explanation
E.2
Supply voltage is too low
E.3
Supply voltage is too high
E.4
Main transformer overheated
E.6
Secondary voltage too high (safety limit 113 V)
E.13
Panel card and control card versions do not match. One of them is AU version and
another one non-AU version.
E.40
IGBT NTC overheated

Other manuals for Kemppi MinarcTig Evo 200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kemppi MinarcTig Evo 200 and is the answer not in the manual?

Kemppi MinarcTig Evo 200 Specifications

General IconGeneral
Input Voltage230 V
Protection ClassIP23
Power Factor0.99
Welding ProcessTIG, MMA
Duty Cycle TIG35% at 200 A
StandardsIEC 60974-1, IEC 60974-10