EasyManua.ls Logo

Kemppi X3 - Page 15

Kemppi X3
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
X3 MIG Welder© Kemppi Oy 2018 1814
OPERATING MANUAL
2T mode and Crater ll function
Push the trigger – welding starts after preset Pre
gas time.
Release the trigger – values drop to preset Crater
ll level and welding ends after preset time. Post
gas ows for preset time.
1. 2. 3.
1. Pre gas time
2. Crater ll time
3. Post gas time
4T mode
MIG welding with 4T mode of the gun trigger.
Trigger pushed down – ow of shielding gas
starts.
Trigger released – welding starts.
Trigger pushed down – welding ends and shield-
ing gas ow continues.
Trigger released – ow of shielding gas ends.
Post gas time at least preset minimum.
1. 2.
1. Pre gas time
2. Post gas time
4T mode and Crater ll function
Trigger pushed down – ow of shielding gas
starts.
Trigger released – welding starts.
Trigger pushed down – welding values change
to Crater ll level.
Trigger released – welding ends. Post gas time
ows for preset time.
1. 2. 3.
1. Pre gas time
2. Crater ll time
3. Post gas time

Related product manuals