10.4 Counting with counting system
y y
Bulk material balance e.g. KERN
KFP
Reference balance KERN CFS
Here pieces of huge quantities will
be counted.
Due to its high resolution it is useful
for accurate determination of the
average piece weight.
Big parts (max > 3kg) are counted
on the weighing bridge.
Smallest parts (max < 3kg) are
counted on the precise KERN CFS.
If in the determination of the aver-
age piece weight no such high
resolution is asked for as that of
the KERN CFS, the reference
formation can also be made in the
bulk material balance.
Zählen mit Mengenwaage:
1. On the reference balance KERN CFS set average piece weight, see chpt. 10.1.
or chpt. 10.2.
2. Switch-over balance with , see chpt. 8.3
3. Put empty vessel on the weighing plate of the bulk material balance KERN KFP
and tare.
4. Fill counted quantity in the vessel on the bulk material balance. The piece num-
ber is shown in the display.
In order to avoid errors at the piece number determination, both balances
must be adjusted with the same acceleration due to gravity (see chpt. 7.1 or
chpt.7.2). In case of non-compliance counting errors will result!
28 CFS/CCS-BA-e-1013

Table of Contents

Other manuals for KERN CFS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KERN CFS and is the answer not in the manual?

KERN CFS Specifications

General IconGeneral
Plate materialstainless steel
Readability0.01 g
Reproducibility0.01g
CalibrationExternal calibration
DisplayLCD
Weighing unitsg, lb, oz
Operating temperature10 °C - 40 °C
Functionscounting, weighing
InterfaceRS-232