202 Keysight InfiniiVision 2000 X-Series Oscilloscopes User's Guide
15 Mask Testing
5 Press Automask.
6 In the Automask Menu, press the Source softkey and ensure the desired analog
channel is selected.
7 Adjust the mask's horizontal tolerance (± Y) and vertical tolerance (± X). These
are adjustable in graticule divisions or in absolute units (volts or seconds),
selectable using the Units softkey.
8 Press the Create Mask softkey.
The mask is created and testing begins.
Whenever the Create Mask softkey is pressed the old mask is erased and a new
mask is created.