EasyManua.ls Logo

Keysight Technologies RP7945A

Keysight Technologies RP7945A
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
:TERMinate
:LAST 0|OFF|1|ON Determines the output value when the list terminates.
:TOUTput
:BOSTep
[:DATA] <Bool>{,<Bool>} Generates a trigger out at the Beginning Of STep
:POINts? Returns the number of list points.
:EOSTep
[:DATA] <Bool>{,<Bool>} Generates a trigger out at the End Of STep
:POINts? Returns the number of list points.
:VOLTage
[:LEVel] <value>{,<value>} Specifies the setting for each list step.
:POINts? Returns the number of list points.
[SOURce:]
POWer
:LIMit? Returns the output power limit of the instrument
[SOURce:]
STEP
:TOUTput0|OFF|1|ON Specifies whether a trigger out is generated when a transient step occurs.
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <value> Sets the output voltage when in voltage priority mode.
:TRIGgered
[:AMPLitude] <value> Sets the triggered output voltage.
:BWIDth LOW|HIGH1 Sets the voltage compensation (RP795xA, RP796xA)
:RANGe 0 | 1 | 2 Sets the voltage compensation. (RP793xA, RP794xA)
:LEVel 0 | 1 | 2, <value> Sets the compensation frequency. (RP793xA, RP794xA)
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value> Sets the voltage limit when in current priority mode.
:LOW <value> Sets the low-voltage limit. (RP793xA, RP794xA)
:MODE FIXed|STEP|LIST|ARB Sets the transient mode.
:PROTection
[:LEVel] <value> Sets the over-voltage protection level.
:LOW
[:LEVel] <value> Sets the low-voltage protection level. (RP793xA, RP794xA)
:DELay <value> Sets the low-voltage protection delay. (RP793xA, RP794xA)
:STATe 0|OFF|1|ON Enables or disables low-voltage protection. (RP793xA, RP794xA)
:RESistance
[:LEVel]
1 Quick Reference
30 Keysight RP7900 Series Operating and Service Guide

Table of Contents