260 
Analog/Digital IF Troubleshooting
40 MHz BW IF Section
Verifying the 300 MHz LO Input Power from the A16 Reference 
Assembly
1. Refer to Figure 6-15, carefully disconnect the W14 at A2J300.
Figure 6-15  A2 Analog IF Cables
2. Connect the W14 cable to the MMCX female to SMA female adapter. Use 
an appropriate cable to go from the SMA adapter to the RF input of a 
functioning spectrum analyzer.
3. Press Freq, 300 MHz, Span, 1 MHz, Amplitude, 10 dBm, Peak Search on 
the functioning spectrum analyzer.