Page 40
Find us at www.keysight.com
For devices with 2.4 mm connectors (Continued)
Cables
Note: Keysight offers the following 2.4 mm test port cables.
Adapters will be necessary when using these cables for 2.92 mm
measurements.
– 85133C
1
single, semi-rigid: 2.4 mm (f) to PSC-2.4 mm (f),
81 cm, 32 inches
– 85133D
1
set, semi-rigid: One 2.4 mm (f) to 2.4 mm (m),
53 cm, 21 inches, p/n 85133-60001
– One 2.4 mm (f) to 2.4 mm (f), 53 cm, 21 inches, p/n
85133-60002
– 85133E
1
single, flexible: 2.4 mm (f) to PSC-2.4 mm (f), 97 cm,
38 inches
– 85133F
1
set, flexible:
– One 2.4 mm (f) to 2.4 mm (f), 63 cm, 25 inches, p/n
85133-60016
– One 2.4 mm (f) to 2.4 mm (m), 63 cm, 25 inches, p/n
85133-60017
– 85133H
1
Single, flexible: 2.4 mm (f) to 2.4 mm (m), 63 cm,
25 inches
– N4421AK20 Single, flexible: 2.4 mm (f) to 2.4 mm (m),
91.4 cm, 36 inches
Adapter set
– 85130E 2.4 mm
1
to 7 mm
– 85130F 2.4 mm
1
to 3.5 mm
– 85130G 2.4 mm
1
to 2.4 mm
For devices with K connectors (2.92 mm)
Mechanical calibration kits
85056KE01 DC to 40 GHz
For use with user supplied 2.92 mm test port cables. 2.92 mm
(K connector) calibration kit with fixed and sliding loads. The
Keysight 85056KE01 calibration kit is an ordering convenience
to allow the pass through ordering from Keysight for the Maury
8770C47 calibration kit.
85056KE02 DC to 40 GHz
For use with user supplied 2.92 mm test ports cables. 2.92 mm
(K connector) calibration kit with fixed loads only. The Keysight
85056KE02 calibration kit is an ordering convenience to allow
the pass through ordering from Keysight for the Maury 8770F47
calibration kit.
The 85056KE01 and 85056KE02 contains one NMD 2.4 mm
2
(f) to 2.92 mm (f) and one NMD 2.4 mm
2
(f) to 2.92 mm (m)
test port adapter to adapt the 2.4 mm test ports of the PNA to
2.92 mm. It also supplies 2.92 mm to 2.92 mm in-series adapters
(3 adapters) and a PNA Cal Coefficients on a USB stick. Users
must supply their own 2.92 mm or K-connector test port cables.
Also included is a 2.92 mm torque wrench.
Maury Microwave Terms and Conditions for Warranty and Return
apply. Maury Microwave Corp. calibration kits are to be returned
directly to Maury Microwave for service, repair, or calibration
issues and not to Keysight Technologies. For additional
information go to www.maurymicrowave.com.
Keysight Technologies does not guarantee the performance
of the Maury calibration kits or the system performance when
connected to Keysight Microwave PNA Series network analyzers.
1. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with a standard male
connector.
2. Special rugged female connector specifically for connecting to the
network analyzer test port, but does not mate with standard 2.4 mm
male connector