2-12
Explosion Hazard
Use a new CSA International approved
gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified
person make sure gas pressure does
not exceed 14˝ (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death,
explosion, or fire.
Convert from Natural Gas to LP Gas
1. Turn manual shutoff valve to the closed
position.
2. Unplug cooktop or disconnect power.
A. To cooktop
B. Shuto valve (closed position)
C. Gas supply line
A
B
C
To Convert Gas Pressure Regulator
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Gas ow
A
B
C
D
3. Determine the type of regulator you
have:
Style 1: The cap has a slot and “NAT” printed
on it.
Remove access cap by using a at-blade
screwdriver or coin, turning the access cap
counterclockwise.
The gas pressure regulator has 2 settings that
are stamped on either side of the cap. Turn the
cap and reinstall into regulator with the stamp
“LP” visible from the outside of the regulator.