4-17
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Unplug dishwasher or disconnect power.
2. Turn off the water supply to the dish-
washer.
3. Remove the dishwasher from its installed
location.
REMOVING THE INLET VALVE / FLOW METER ASSEMBLY
6. Remove the retainers from the tube ends.
Tube Retainer
Tube Retainer
Wire Connectors
Inlet Valve
Tube Retainer
4. Disconnect the wire connectors from the
inlet valve and flow meter terminals.
5. Remove the screws from the inlet valve
and remove the valve.
Inlet Valve
Screws