Lifting motor (Dual speed)
Capacity
(t)
Code
Motor
output
(kW)
230V Class 400V Class
230/460V Class
500V Class
220–230V 380–415V 380–440V 208-230V 415-460V 500V 575V
50Hz 60Hz 50Hz 60Hz 60Hz 50Hz 60Hz
125kg
MR2-010S/L
0.4 3.3 3.0 2.3 2.2 3.2 1.6 1.5 1.1
250kg
500kg
1
1.5
MR2-020S/L
2
2.5
MR2-030S/L
2.8
3
5
MR2-050S/L
0.75 5.1 4.8 3.8 3.3 5.1 2.5 2.2 1.8
Motor Insulation Class B F B B
■
Traveling motor (Single speed)
■
Traveling motor (Dual speed)
(to be continued)
A
Technical Material
Capacity
(t)
Code
Motor
output
(kW)
230V Class 400V Class 230/460V Class 500V Class
220-230V
380–
415V
380–
440V
208-230V 415-460V
Motor
output
(kw)
500V 575V
60Hz 50Hz 60Hz
125kg
MR2-010IS
0.4 3.5 2.5 3.4 1.7
0.32
/0.08
1.7/1.0 1.1/0.8
250kg
500kg
1
1.5
MR2-020IS
2
2.5
MR2-030IS
0.64/
0.16
1.9/1.5 1.3/1.1
2.8
3
5
MR2-050IS
0.75 5.4 4.0 5.4 2.7
Motor Insulation Class B F B B
Capacity
(t)
Code
Motor
output
(kW)
230V Class 400V Class
230/460V Class
500V Class
220–230V
380–
415V
380–
440V
208-230V 415-460V
Motor
output
(kW)
500V 575V
60Hz 50Hz 60Hz
125kg ER2-001IH
0.56 4.0 2.7 3.6 1.8 0.5 1.6/0.9 1.4/0.9250kg ER2-003IS
500kg ER2-005IL
250kg ER2-003IH
0.9 5.3 3.6 5.1 2.7 0.9 1.8/1.4 1.7/1.4500kg ER2-005IS
1
ER2-010IL
ER2-010IS
1.8 8.8 5.1 9.1 4.5 1.8 3.2/2.2 3.2/2.01.5 ER2-015IS
2
ER2-020IL
ER2-020IS
3.5 16.2 9.2 17.3 8.3 3.5 6.0/3.7 6.0/3.4
2.5 ER2-025IS
2.8 ER2-028IS
3 ER2-030IS
5 ER2-050IS
Motor Insulation Class B F B B
(Unit:A)
(Unit:A)
(Unit:A)

Table of Contents