3.8. Electric wiring
3.8.1. 3.8.1 General cautions for electric wiring
Check that the power supply is in accordance with the specification on the
name plate (AC230V/50Hz).
Incorrect supply voltage can cause fire.
Use an independent power receptacle, safe from rain and moisture.
Do not connect ground cable to a lightening arrestor or fuel pipe.
Otherwise, the product may fail or even exploded.
Boilers must be grounded to prevent electric shock or other accident by
leakage current.
For the 230V power supply, grounding and cable works, observe the
applicable laws and regulations.
If the 230V power supply is obtained by individual voltage raise in a 110V
region, make sure to provide a ground connection.
In this case, the capacity of the voltage step up transformer must be at least
1kW.
Power receptacle must be away from the boiler by at least 300 mm.
The grounding point must be at 300 mm or deeper in the ground.