SANARIUM M, S
PAGE 21
5070189/02.03
6. Individual settings
Button: Description:
A Light button
B Operatingmodebutton
C Left/Right buttons
D Up/Down buttons
E OK button
Programs:
Sauna temperature:
SANARIUM temperature: Humidity
1 Individual program 1 Individual program Individual program
280°C 250°C
approx. 35 g/m
3
390°C 355°C approx. 50 g/m
3
495°C 460°C approx. 70 g/m
3
570°C approx. 70 g/m
3
6.1. Selecting the program
RISK OF FIRE!
Before operating the control unit, always make sure that there are no combustible
objects on or near the sauna heater.
1. To select the menu, use the left/right buttons.
2. Use the up/down
buttons to select the program.
. The value that can be changed flashes.
3. Confirm the selection using the
button.
. The flashing value changes to continuous display. The selected bathing program is started once the
selection has been confirmed.
6.2. Setting the temperature
1. To select the menu, use the left/right buttons.
. The value that can be changed flashes.
2. Use the up/down
buttons to change the flashing value.
3. Confirm the set value using the
button.
. If the value deviates from a standard program, the value will automatically be stored in the
individual program of the active bathing program (Sauna or SANARIUM).
At a maximally set nominal temperature of 110 °C, a maximum cabin temperature of
100 °C is achieved depending on the size of the cabin and heater model.
If the value deviates from a standard program, the value will automatically be stored in
the individual program of the active bathing program (Sauna or SANARIUM).