EasyManua.ls Logo

Kold-Draft GB564AC - Start Methods; Ice Making Mode Start up; Cleaning Mode Start up

Default Icon
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
new 60 Series Service Manual.rev. 06.01.16.docx - 29
START METHODS
Ice Making Mode Start Up
At power up in the ice making mode the electronic control will monitor the following
criteria:
If the evaporator temperature is colder than the Harvest Termination temperature at start up the
controller will switch to the Lower state.
If there is an obstruction preventing the water plate from closing the Plate Up switch at startup,
the controller will switch to the Lower state.
If the water plate is not in the up position at start up and the evaporator temperature is warmer
than the Harvest Termination temperature, the controller will switch to the Raise state.
Cleaning Mode Start Up
At power up in the wash mode the electronic control will monitor the following criteria:
If there is an obstruction preventing the water plate from closing the Plate Up switch at startup,
the controller will switch to the “Lower” state.
If the water plate is not in the up position at start up, the controller will switch to the “Raise” state.

Table of Contents

Related product manuals