98
If there is ice on the surface of the water plate, preventing it from closing, the controller will reopen
the plate to clear it.
Storage and Winterization
Clean and sanitize the ice machine.
Disconnect the electric power supply.
Disconnect water and drain lines.
Remove and empty the water sump.
Open water valve and dump valve and blow compressed air through all lines.
Remove and drain the water plate assembly.
Reassemble water plate assembly and water sump.
Replace all cabinet panels.
Removal from Service
When the ice maker is determined to be no longer useable please be sure that it is rendered safe for
storage or disposal. All applicable recycling measures should be exercised to avoid injury and harm
to the environment.
The manufacturer and/or seller are not responsible for any harm to people, animals, property, and
the environment caused by incorrect installation and/or disposal
Wiring Diagram