20. Pull the cable out through the front of the crusher control box and cut off the cable to a
manageable length.
21. Strip the outer cable jacket back about 3”. Then strip the red and black wires back about ¼”.
22. Connect the stripped wires to the left relay as shown.
23. Turn off the breaker or disconnect the fuse that will service the machine.
24. Make all electrical connections to the electrical service in a manner that complies with
local code
Note:
• If two separate ice making machines (for example two GB1064 models stacked) are
installed the bin thermostats of both ice makers will need to be connected to the crusher.
• Ensure that the thermostat cable is not routed through the ice chute. Do not run the cable
through the same hole that the safety switch wire assembly and the motor control wire
assembly are run through.
Initial Start-Up
1. Ensure all electrical connections were made properly and turn on the electrical service.
Note: There is no on-switch, the machine will run when the ice-maker tells it to.
2. Adjust the bin thermostat to turn off the ice maker before the ice level is above the guard
screen.
3. Adjust the thermostats to shut off the ice maker approximately 1 minute after the ice contacts
the capillary tubes.
Note:
• If ice is allowed to collect above the screen it will not clear when the ice below is removed.
This condition will cause ice to pile up in the chute of the crusher and ultimately, damage
the ice maker