• All KOLD-DRAFT models are intended to be installed with a permanent connection to the field
electrical supply. See rating plate on the back of the machine for power supply requirements.
• Each ice maker must be connected to a separate protected circuit with no other loads.
• Fused disconnects, installed adjacent to each ice maker, are recommended and may be required
by local codes. These components must be supplied by the installer.
• Electrical service must fall within the voltage tolerances listed below:
Maximum Overload Protection must be no greater than specified. The minimum circuit ampacity
specified does not indicate a typical running current value. Use the minimum ampacity value for
sizing branch circuit conductors up to 26 feet (8 meters) in length. For a conductor length over
this length, increase the wire gauge as required by code.
Ice Cube Information
Operation
Initial Start Procedure
11. Be sure that the on-off switch is in the “off” position and the ice-clean switch is in the “ice” position.
12. Make sure all water lines and hoses are securely connected, turn on water supply and check for
leaks.
13. Move the on-off switch to the “on” position and observe the water plate opening. Any water in the
tank will then be drained. The compressor will turn on, the water plate will close and the sump
tank will start to fill.