2.2 Use as directed
l
The servo amplifiers are components which are built into electrical equipment or machines,
and can only be used as integral components of such equipment.
l
The manufacturer of the machine must generate a hazard analysis for the machine, and take
appropriate measures to ensure that unforeseen movements cannot cause injury or damage to
any person or property.
l
The SERVOSTAR 600 family of servo amplifiers (overvoltage category III acc. to EN
61800-5-1) can be connected directly to symmetrically earthed (grounded) three-phase indu
-
strial mains supply networks [TN-system, TT-system with earthed (grounded) neutral point, not
more than 42,000 rms symmetrical amperes, 480VAC maximum].
Connection to different mains supply networks (with additional isolating transformer) ð p.48.
l
Periodic overvoltages between outer conductor (L1, L2, L3) and housing of the servo amplifier
may not exceed 1000V (peak value).
Transient overvoltages (< 50µs) between the outer conductors may not exceed 1000V.
Transient overvoltages (< 50µs) between outer conductors and housing may not exceed
2000V.
l
If the servo amplifiers are used in residential areas, or in business or commercial premises,
then additional filter measures must be implemented by the user.
l
The SERVOSTAR 600 family of servo amplifiers is only intended to drive specific brushless
synchronous servomotors, with closed-loop control of torque, speed and/or position. The rated
voltage of the motors must be at least as high as the DC bus link voltage of the servo amplifier.
l
The servo amplifiers may only be operated in a closed switchgear cabinet, taking into account
the ambient conditions defined on page 24 and the dimensions shown on page 36. Ventilation
or cooling may be necessary to prevent enclosure ambient from exceeding 45°C (113°F).
l
Use only copper wire. Wire size may be determined from EN 60204 (or table 310-16 of the
NEC 60°C or 75°C column for AWG size).
l
Consider the specifications on page 92 when you use the optional personnel safe restart lock
-AS-.
2.3 Prohibited use
l
Other use than described in chapter 2.2 is not intended and can lead to damage of persons,
equipment or things.
l
The use of the servo amplifier in the following environments is prohibited:
- potentially explosive areas
- environments with corrosive and/or electrically conductive acids, alkaline solutions,
oils, vapours, dusts
- directly on non-grounded supply networks or on asymmetrically grounded supplies
with a voltage >240V.
- on ships or off-shore applications
l
Commissioning the servo amplifier is prohibited if the machine in which it was installed,
- does not meet the requirements of the EC Machinery Directive
- does not comply with the EMC Directive or with the Low Voltage Directive
- does not comply with any national directives
l
The control of holding brakes by the SERVOSTAR 600 alone may not be used in applications,
where personnel security is to be ensured with the brake.
Safety instructions
12 SERVOSTAR
®
601...620 Instructions Manual
Safety
07/2010 Kollmorgen