Kramer Electronics Ltd.
SL-280Protocol 3000
46
COM-ROUTE
Functions
Permission
Transparency
Set:
Get:
COM-ROUTE?
End User
Internal
Description
Syntax
Set:
Get:
Get tunneling port
routing
#COM-ROUTE?COM_Num
Response
~nn
@COM-ROUTE
COM_Num,portType,ETHPort,ETH_rep_en,TCP_keep_alive_timing
␍␊
Parameters
COM_Num
SERIAL
port number: 18, * (get all route tunnels)
portType1 (UDP), 2 (TCP)
ETHPortTCP/UDP port number: default = 50015008
ETH_rep_en1 (COM port sends replies to new clients) 0 (COM port does not send replies to new
clients)
TCP_keep_alive_timingevery x seconds the device sends an empty string to TCP client ("/0"):
0
3600
seconds
Response Triggers
Notes
This command gets tunneling port routing. Every SERIAL port can send or receive data from the ETH port.
Example
Get tunneling port routing through SERIAL port number 1:
#COM-ROUTE?
1
<CR>