ELECTRICAL CONNECTIONS 3
23
OPTISONIC 8300
www.krohne.com03/2020 - 4008065101 - QS OPTISONIC 8300 R01 en
3.5.4 Alterable input/output versions
This signal converter is available with various input/output combinations.
The grey boxes in the tables denote unassigned or unused connection terminals.
In the table, only the final digits of the CG no. are depicted.
Term. = (connection) terminal
CG no. Connection terminals
A+ A A- B B- C C- D D-
Modular IOs (option)
4 _ _ max. 2 optional modules for term. A + B
I
a
+ HART
®
active
P
a
/ S
a
active
1
8 _ _ max. 2 optional modules for term. A + B
I
p
+ HART
®
passive
P
a
/ S
a
active
1
6 _ _ max. 2 optional modules for term. A + B
I
a
+ HART
®
active
P
p
/ S
p
passive
1
B _ _ max. 2 optional modules for term. A + B
I
p
+ HART
®
passive
P
p
/ S
p
passive
1
7 _ _ max. 2 optional modules for term. A + B
I
a
+ HART
®
active
P
N
/ S
N
NAMUR
1
C _ _ max. 2 optional modules for term. A + B
I
p
+ HART
®
passive
P
N
/ S
N
NAMUR
1
FOUNDATION Fieldbus (option)
E _ _ max. 2 optional modules for term. A + B V/D+ (2) V/D- (2) V/D+ (1) V/D- (1)
Modbus (option)
G _ _
2
max. 2 optional modules for term. A + B Common Sign. B
(D1)
Sign. A
(D0)
H _ _
3
max. 2 optional modules for term. A + B Common Sign. B
(D1)
Sign. A
(D0)
1 Changeable
2 Not activated bus terminator
3 Activated bus terminator

Other manuals for KROHNE OPTISONIC 8300