V - 7
Working with the Big Pack Baler
5.4.3 Electric Twine Fault Display
If the end of the twine has been reached or the twine is
broken, the sprung twine tensioners (1) auf den Dreh-
winkel (2) ablegen. Es ertönt am Bedienpult ein akusti-
sches Warnsignal. Im Display erscheint eine Fehlermel-
dung.
To switch off the acoustic warning
signal while threading the twine, see
Chapter "Alarm Messages".
Die Einstellung der Garnbremsen (siehe Kap. 6.4)
erfolgt durch Verdrehen der Einstellschrauben (1).
5.4.4 Initiating the Binding Process Manually
For the twine to enter the bale channel and to be taken
by the knotter, the binding process must be initiated
manually. To do this, first swing the safety lever (2)
downwards. Move lever (1) upwards to initiate the bin-
ding process. Move the needles upwards to the knot-
ters manually at the flywheel (in the working direction)
or by switching on the PTO shaft. The binding twine is
now in the bale channel.
BP380-7-051
2
1