11 Trouble-shooting
80 of 88
BoosterControl Advanced
Fault message Description Type of message
Warning Alert
Under voltage P2 DC link voltage too low, frequency inverter 2 ✘ -
Under voltage P3 DC link voltage too low, frequency inverter 3 ✘ -
Under voltage P4 DC link voltage too low, frequency inverter 4 ✘ -
Over voltage P5 DC link voltage too low, frequency inverter 5 ✘ -
Over voltage P6 DC link voltage too low, frequency inverter 6 ✘ -
Overload Failure P1 Overload, frequency inverter 1 ✘ -
Overload Failure P2 Overload, frequency inverter 2 ✘ -
Overload Failure P3 Overload, frequency inverter 3 ✘ -
Overload Failure P4 Overload, frequency inverter 4 ✘ -
Overload Failure P5 Overload, frequency inverter 5 ✘ -
Overload Failure P6 Overload, frequency inverter 6 ✘ -
Brake resistor P1 Braking resistor fault, frequency inverter 1 ✘ -
Brake resistor P4 Braking resistor fault, frequency inverter 2 ✘ -
Brake resistor P3 Braking resistor fault, frequency inverter 3 ✘ -
Brake resistor P4 Braking resistor fault, frequency inverter 4 ✘ -
Brake resistor P5 Braking resistor fault, frequency inverter 5 ✘ -
Brake resistor P6 Braking resistor fault, frequency inverter 6 ✘ -
Temp. Failure P1 Temperature too high, frequency inverter 1 ✘ -
Temp. Failure P2 Temperature too high, frequency inverter 2 ✘ -
Temp. Failure P3 Temperature too high, frequency inverter 3 ✘ -
Temp. Failure P4 Temperature too high, frequency inverter 4 ✘ -
Temp. Failure P5 Temperature too high, frequency inverter 5 ✘ -
Temp. Failure P6 Temperature too high, frequency inverter 6 ✘ -
ATM Failure P1 Automatic motor adaptation fault, frequency inverter 1 ✘ -
ATM Failure P2 Automatic motor adaptation fault, frequency inverter 2 ✘ -
ATM Failure P3 Automatic motor adaptation fault, frequency inverter 3 ✘ -
ATM Failure P4 Automatic motor adaptation fault, frequency inverter 4 ✘ -
ATM Failure P5 Automatic motor adaptation fault, frequency inverter 5 ✘ -
ATM Failure P6 Automatic motor adaptation fault, frequency inverter 6 ✘ -
Flushing Flushing procedure active ✘ -
Valve opened oftenly Several flushing procedures carried out ✘ -
Circuit Fail. FC1 Short circuit/earth fault, frequency inverter 1 ✘ -
Circuit Fail. FC2 Short circuit/earth fault, frequency inverter 2 ✘ -
Circuit Fail. FC3 Short circuit/earth fault, frequency inverter 3 ✘ -
Circuit Fail. FC4 Short circuit/earth fault, frequency inverter 4 ✘ -
Circuit Fail. FC5 Short circuit/earth fault, frequency inverter 5 ✘ -
Circuit Fail. FC6 Short circuit/earth fault, frequency inverter 6 ✘ -
Ext. Power Operation Emergency power mode active; maximum system load
limited
✘ -
Setpoint Reduction Setpoint reduced due to drop in inlet pressure ✘ -
Factory Test No test carried out in factory - ✘
MPO Failure Fault in VP mode, synchronous operation ✘ -
ASR Shutdown Cancellation of automatic setpoint reduction - ✘