18. STARTING SYSTEM
18-5
MXU 300/250
Check for continuity between the brushes. If
there is continuity, replace with new ones.
Check if the needle bearing in the front
cover turns freely and has no excessive
play.
Replace if necessary.
Check the dust seal for wear or damage.
ASSEMBLY
Apply grease to the dust seal in the front
cover.
Install the brushes onto the brush holders.
Apply a thin coat of grease to the two ends
of the armature shaft.
Insert the commutator into the front cover.
Front Cove
r
Commutato
r
Bearin
g
Dust Seal
Be careful not to damage the brush and
armature shaft mating surfaces.
When installing the commutator, the
armature shaft should not damage the
dust seal lip.