2M8/2M9
1-3-70
Developer
Setting
Entering initial value for replacing the developing unit
Description
After replacing the developing unit, enter the initial value (6-digit data) assigned on a
label attached to the package or developing unit.
Purpose
To set the initial value after replacing the developing unit.
Method
1. Enter the Service Setting menu.
2. Select [DeveloperSetting].
3. Press the start key.
Enter the initial value (6-digit data) using the numeric keys.
4. Press the start key. The initial value is set.
Figure 1-3-7
Completion
Press the stop key.
Service items Description
DV560Y
DV560M
Label
Package
Developing unit