2M8/2M9
1-4-16
3100 ISU home position error
The home position is not cor-
rect when the power is turned 
on or at the start of copying 
using the table.
Defective connec-
tor cable or poor 
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none, 
replace the cable.
Home position sensor and CCD PWB (YC3)
CCD PWB (YC1) and main PWB (YC8)
ISU motor and main PWB (YC36)
Defective home 
position sensor.
Replace the home position sensor.
Defective ISU 
motor.
Replace the ISU motor.
Defective CCD 
PWB.
Replace the scanner unit (see page 1-5-48).
Defective main 
PWB.
Replace the main PWB and check for cor-
rect operation (see page 1-5-30).
3200 Exposure lamp error
The exposure lamp does not 
turn on when power is on.
The lamp’s lumosity does not 
stabilize in one minute after 
power is on.
Defective connec-
tor cable or poor 
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none, 
replace the cable.
LED PWB and LED driving PWB (YC2)
LED driving PWB (YC1) and CCD PWB 
(YC3)
CCD PWB (YC1) and main PWB (YC8)
Defective LED 
PWB.
Replace the scanner unit (see page 1-5-48).
Defective LED 
driving PWB or 
CCD PWB.
Replace the scanner unit (see page 1-5-48).
Defective main 
PWB.
Replace the main PWB and check for cor-
rect operation (see page 1-5-30).