2LK/2LN/2LM/2LC-2
1-3-72
U100 Setting: [Set Charger Freq]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.ll
*: 55 ppm model only.
3. Press the start key. The value is set.
Displaying: [Chk Current]
1. The current setting is displayed.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for maintenance item No. is displayed.
Item No. Description
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Generally Main charger frequency 7500 to
11280
10442 8857 8807 11022
B/W* Main charger frequency in
black/white mode
7500 to
11280
- - - 10690
Half Main charger frequency in
half speed
7500 to
11280
10690 10690 10690 10690
3/4 Main charger frequency at
3/4 times of line speed
7500 to
11280
10690 10690 8857 8857
Display Description
C Cyan rush current
M Magenta rush current
Y Yellow rush current
K Black rush current