2LK/2LN/2LM/2LC-2
1-3-73
U101 Setting the voltage for the primary transfer
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Setting
1. Press the start key.
2. Select the item to be set.
Setting: [Normal]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.ll
3. Press the start key. The value is set.
Setting: [Add Color]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.l
3. Press the start key. The value is set.
Item No. Description
Display Description
Normal Setting the primary transfer positive voltage
Add Color Setting the addition value
Add Color 2nd Setting the addition value for the second side
Surround Correct Environmental correction ON/OFF setting
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Full Primary transfer positive volt-
age for yellow (full speed)
0 to 255 114 118 126 131
Half Primary transfer positive volt-
age for yellow (half speed)
0 to 255 101 103 108 110
3/4 Primary transfer positive volt-
age for yellow at 3/4 times of
line speed
0 to 255 158 158 158 158
Display Description
Setting
range
Initial
setting
C Addition value (cyan) -127 to 127 2
M Addition value (magenta) -127 to 127 2
Y Addition value (black) -127 to 127 5