2LK/2LN/2LM/2LC-2
1-3-81
U107 Setting the transfer cleaning voltage
Description
Sets the cleaning control voltage for transfer belt unit.
Purpose
Change settings if an offset has occurred due to the failure of cleaning the transfer belt.
Method
1. Press the start key.
2. Select the item to be set.
3. Select the item to be set.
4. Change the value using the +/- or numeric keys.l
[Belt(A)]
[Belt(B)]
5. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt
copying mode (which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Belt(A) Transfer belt cleaning voltage (printing)
Belt(B) Transfer belt cleaning voltage (paper interval)
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Full Full speed 0 to 255 187 192 202 207
Half Half speed 0 to 255 172 175 180 182
3/4 3/4 times of line speed 0 to 255 187 192 202 212
B/W Black/white mode 0 to 255 182 182 192 192
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Full Full speed 0 to 255 120 130 150 160
Half Half speed 0 to 255 100 100 110 110
3/4 3/4 times of line speed 0 to 255 120 130 150 160
B/W Black/white mode 0 to 255 110 110 130 130