2LK/2LN/2LM/2LC-2
1-3-83
U108 Setting: [Output 3/4 / Output B/W]
1. Select the item to be set.
2. Change the setting value using the +/- or numeric key.
3. Press the start key. The value is set.
Setting: [Timing]
1. Select the item to be set.
2. Change the setting value using the +/- or numeric key.
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Setting
range
Initial
setting
Light 1st Separation shift bias for the first side on
paper with thickness 52 to 59 g/m
2
0 to 255 20
Light 2nd Separation shift bias for the second side
on paper with thickness 52 to 59 g/m
2
0 to 255 20
Normal 1st Separation shift bias for the first side on
paper with thickness 60 to 75 g/m
2
0 to 255 20
Normal 2nd Separation shift bias for the second side
on paper with thickness 60 to 75 g/m
2
0 to 255 20
Display Description
Setting
range
Initial
setting
On Timing Lead Separation shift bias ON timing at lead-
ing edge of paper
-200 to 200 0
On Timing
Center
Separation shift bias ON timing at center
of paper
-200 to 200 0
Off Timing Separation shift bias OFF timing -200 to 200 0