2LK/2LN/2LM/2LC-2
1-3-97
U140 Method: [High Altitude]
1. Select Mode1 or Mode2.
Initial setting: Mode1
2. Press the start key. The value is set.
3. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
Method: [AC Calib] (30 ppm model/35 ppm model)
1. Select the item.
Method: [High Altitude]
1. Select mode.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Mode1 Execute AC calibration by normal bias control
Mode2 If print density is low in an installation at high altitude, execute
calibration by fixing the bias potential.
Display Description
High Altitude Mode setting for AC calibration bias control
Display Description Display Description
Default Initial setting 3000m Settings equivalent to
the altitude of 3000 m.
1000m Settings equivalent to the
altitude of 1000 m.
4000m Settings equivalent to
the altitude of 4000 m.
2000m Settings equivalent to the
altitude of 2000 m.