EasyManua.ls Logo

Kyocera TASKalfa 3050ci - Page 197

Kyocera TASKalfa 3050ci
936 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2LK/2LN/2LM/2LC-2
1-3-103
U161 Setting the fuser control temperature
Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper,
or solve a fuser problem on thick paper.
Method
1. Press the start key.
2. Select the item to be set.
Setting: [Warm Up]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
3. Press the start key. The value is set.
Item No. Description
Display Description
Warm Up Control temperature except at printing
Print Control temperature during printing
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Ready
(Center)
Control temperature at dis-
playing Ready (Center)
130 to 200
(°C)
155 160 165 170
Ready
(Edge)
Control temperature at dis-
playing Ready (Edge)
100 to 200
(°C)
110 110 140 145
Ready
(Press)
Control temperature at dis-
playing Ready (Press)
0 to 200
(°C)
40 40 80 80
Drive
(Center)
Stable temperature during
driving (Center)
130 to 200
(°C)
165 170 170 175
Wait
(Center)
Stable temperature during
halt (Center)
130 to 200
(°C)
155 165 165 175
Low Power
(Press)
Control temperature at low
power consumption
(Press)
0 to 200
(°C)
150 150 150 150
Full Speed
Shift(Center)
Full speed shift tempera-
ture (Center)
0 to 200
(°C)
50 50 50 50
Pressure
(Press)
Pressurizing beginning
temperature (Press)
0 to 200
(°C)
120 120 155 160

Table of Contents