2LK/2LN/2LM/2LC-2
1-3-104
U161 Setting: [Print]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U163 Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
Item No. Description
Display Description
Setting
range
Initial setting
30ppm 35ppm 45ppm 55ppm
Full Speed
Print(Center)
Temperature at maximum
print speed (Center)
130 to 200
(°C)
165 170 170 175
Duplex Shift
(Center)
Temperature at duplex
printing (Center)
-20 to 20
(°C)
5555