2LK/2LN/2LM/2LC-2
1-3-105
U167 Checking/clearing the fuser count
Description
Displays and clears the fuser count for checking.
Purpose
To check the fuser count or drive time after replacement of the fuser unit. Also to clear the counts
after replacing unit.
Method
1. Press the start key. The fuser count is displayed.
Clearing
1. Press [Clear].
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U169 Checking/setting the fuser power source
Description
Displays and settings the specification of fuser power supply for checking.
Purpose
To check or set the specification of fuser power supply after replacement of the fuser unit.
Method
1. Press the start key.
2. Select the mode.
1: 100 V specifications 2: 200 V specifications 3: 120 V specifications
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Cnt Fuser unit count value
Release(Time) Fuser unit drive time (release)
Press(Time) Fuser unit drive time (press)
Display Description Setting range
Mode Specification of fuser power supply 1 to 3