37
RV. The RED Gas LED will continue to flash until the gas has
cleared, or the gas alarm will reactivate in approximately 5 minutes if
the gas is still present. DO NOT RE-ENTER THE RV. This alarm will
return to normal operation after the RV is properly ventilated.
MALFUNCTION/SERVICE SIGNAL. If any malfunction is detected,
the Gas LED will remain off and the Operational/CO LED will
alternate Red/Green and the alarm will sound once every 15
seconds. Press the Test/Mute button. If the Test/Mute button does
not clear signals, check the battery voltage. If the battery voltage is
not low and the unit will not return to normal operation,
immediately remove the alarm and return for service or
warranty replacement.
OPERATION AUDIBLE SIGNAL VISUAL SIGNAL
NORMAL NONE STEADY GREEN
CO ALARM 4”BEEPS” STEADY RED
5 SECONDS OFF
PROPANE ALARM CONSTANT FLASHING RED
ALARM “BEEP” EVERY ALTERNATING
MALFUNCTION 30 SECONDS RED/GREEN
Smoke Alarm
Smoke alarms are placed on the ceiling between the sleeping area
and cooking area of each RV built.
Operation: The smoke alarm is in operation once the battery is
correctly connected. The LED will flash every minute to show the
battery is supplying power to the alarm. When production of
combustion are sensed, the unit sounds a loud alarm which
continues until the air is cleared.
False Alarm “Mute” Controls: Models (S/SLL) with the mute
feature have the capability of temporarily reducing the sensitivity of
the alarm circuit for approximately 10 minutes. This feature is to be
used only when a known alarm condition such as smoke from
cooking activates the smoke alarm. The smoke alarm is muted by
pushing and holding the test button on the alarm cover for 5
seconds. The smoke alarm will automatically reduce sensitively and
the LED will “flash” every 10-20 seconds for approximately 10