Setup Records Supplemental Information
E-8
Channel Parameters
Use the following table to select setup record parameters for Channels 1 and 2:
Table E-4: Channel Parameters
Byte(s)
(Channel 1)
Byte(s)
(Channel 2)
Function
16 64 Interface Mode (see Table E-5: Interface Mode Options)
17 65 Line Speed
Bits 7-5: Reserved
Bits 4-0: Baud Rate (see Table E-7: Baud Rate Settings)
18 66 Flow Control (see Table E-8: Flow Control Options)
19 67 Reserved
20-21 68-69 Own TCP port low-byte, high-byte (Intel)
22-23 70-71 Remote TCP port low byte, high-byte (Intel)
24-27 72-75 Remote IP address (low/high low/high)
28 76 Connect Mode (see Table E-9: Connect Mode Options)
29 77 Disconnect Mode (see Table E-10: Disconnect Mode Options)
30 78 Disconnect w/ inactivity time-out, minutes (00 if unused)
31 79 Disconnect w/ inactivity time-out, seconds (00 if unused)
32-33 80-81 Characters to trigger send immediately (sendchar)
34 82 Flush mode (see Table E-11: Flush Mode Options)
35 83 Pack Control (see Table E-12: Pack Control Options)
36-47 84-95 Reserved (0)
48-63 96-111 a) Terminal name for Telnet terminal type option (15 characters
max), 0-terminated. If set and Bit 6 in Disconnect Mode is set,
Telnet connection will be assumed.
b) Password for Passworded Socket Connection (Bit 4 in Dis-
connect Mode Set).