EasyManua.ls Logo

Lantronix EDS32PR - Figure 7-7. Tunnel - Start;Stop Chars

Lantronix EDS32PR
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide 60
Figure 7-7. Tunnel – Start/Stop Chars Page
Tunnel – Start/Stop Chars Page
Tunnel –
Start/Stop Chars
Page Settings
Description
Start Character Enter the start character. When this character is read on the
serial line, it either initiates a new connection (for a tunnel in
Connect mode) or enables a tunnel in Accept mode to start
listening for connections. Default is <none>.
Stop Character Enter the stop character. When this character is read on the
serial line, it disconnects an active tunnel connection. Default is
<none>.
Echo Start
Character
Select whether the start character is forwarded (or “echoed’)
through the selected tunnel when the serial line is read. Choices
are:
On = echo the start character on the selected tunnel when the
serial line is read.
Off = do not echo the start character. (default)
Echo Stop
Character
Select whether the stop character is echoed through the
selected tunnel when the serial line is read. Choices are:
On = echo the stop character on the selected tunnel when the
serial line is read.
Off = do not echo the stop character. (default)

Table of Contents