EasyManuals Logo

Lantronix EDS32PR User Manual

Lantronix EDS32PR
175 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #70 background imageLoading...
Page #70 background image
7: Network, Line, Tunnel, and Terminal Settings
EDS Device Servers User Guide 70
Tunnel – Modem Emulation Page
Tunnel – Modem
Emulation Page
Settings
Description
Echo Pluses Select whether the modem plus (+) command is echoed (sent).
Choices are:
On = modem pluses are echoed.
Off = modem pluses are not echoed. (default)
Echo Commands Select whether modem commands are echoed on the serial line.
Choices are:
On = modem commands are echoed. (default)
Off = modem commands are not echoed.
Verbose Response
Codes
Select whether modem response (result) codes are sent on the
serial line. Choices are:
On = modem responses are sent on the serial line. (default)
Off = modem responses are not sent.
Response Codes Select whether modem response (result) codes sent on the serial
line take the form of words or numbers. Choices are:
Text = modem responses are sent as words. (default)
Numeric = modem responses are sent as numbers.
Error Unknown
Commands
Select whether an ERROR or OK response is sent in reply to
unrecognized AT commands. Choices are:
On = ERROR is returned for unrecognized AT commands.
Off = OK is returned for unrecognized AT commands. (default)
Connect String If required, enter a customized string that is sent along with the
CONNECT response code. Default is <none>.
Tunnel – AES Keys Page
Four Advanced Encryption Standard (AES) Encryption Keys are used for tunneling.
Connect mode and Accept mode contain their own sets of keys. One key is used for
encrypting outgoing data and another key is used for decrypting incoming data. These
AES keys are fixed at 16 bytes. Any keys entered that are less than 16 bytes long are
padded with zeroes.
If you click AES Keys at the top of one of the Tunnel pages, the Tunnel – AES Keys
page displays. Here you can enter key data as text or binary values for the tunnel
selected at the top of the page. Binary values are a string of characters representing
hexadecimal or decimal values.
Notes:
Keys are shared secret keys that must be known by both sides of the connection
and kept secret.
Tunneling using AES encryption uses a non-standard protocol and shared keys,
making it not very secure. The EDS also supports SSH as an alternative method
of secure tunneling. SSH tunneling has the advantage of not using shared keys.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lantronix EDS32PR and is the answer not in the manual?

Lantronix EDS32PR Specifications

General IconGeneral
CertificationUL/CUL, FCC, CE, TUV, C-Tick, GS, CB scheme, VCCI FCC Part 15 Statement Class A Device, ICES-003 Class A Device, C-Tick, VCCI, CE Marking, UL-CUL Mark, TUV-GS Mark, RoHS FCC CFR 47 Part 15 Subpart B, ICES-003 Issue 4, AS/NZS CISPR 22, VCCI V-3, EN55022, EN61000-3-2, EN61000-3-3, EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11
Networking standardsIEEE 802.3
Serial interface typeRS-232
Serial ports quantity32
Ethernet LAN data rates10, 100 Mbit/s
Cabling technology10/100Base-T(X)
USB 2.0 ports quantity0
Ethernet LAN (RJ-45) ports1
Security algorithmsSSH
Supported network protocolsHTTP, HTTPS, FTP, TFTP, Telnet, TCP, UDP, LPD, XML, DHCP, SSHv2, SSLv3, SNMPv2, AutoIP, RSS, ARP, ICMP, SYSLOG, AES, SMTP, DNS, BOOTP, Traceroute
Built-in processorIntel XScale IXP420
Processor frequency266 MHz
Compatible operating systemsWindows 98/ME/NT/2000/XP/Vista
Flash memory8 MB
RAM capacity64 MB
LED indicatorsLAN
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Input voltage100 - 240 V
SafetyUL 60950-1, CSA-22.2 No.60950-1-03, EN60950-1, CB Report - IEC 60950-1