April 8, 2011 HN FAQ Memo, Version 2.0 Page 47 of 108
The amount should not deviate far from these nominal values.
Parlour : Main Line : app. 315ml Dosage Line: 370 ml.
VMS: Main Line : app. 315ml Dosage Line: 370 ml.
Step 6:
If the water amount is to low, look for clogging, bended tubes or leaks in the system.
If both amounts are to low: look in SI, tube from SI to AI, and Manifold.
If Main line is ok, and Dosage is low, look in needle or tubes from manifold to needle.
If Dosage line is ok, and main line is low. Look in mainline stop valve, tubes connected to this
valve or in the manifold.
Refer to Chapter 3.2.1Procedure for complete cleaning of milk transport system between SI and
AI.