PowerTrace Serial User´s Guide 1 9
©1989-2018 Lauterbach GmbH
4 001 100 1.0 0 1.0 FR4 and less than 5inch 4mil
traces
5 100 010 1.0 -3.5 0.7 FR4 and 10inch 4mil traces
6 010 010 1.0 -6 0.5 FR4 and 15inch 4mil traces
7 000 010 1.1 0 1.1 FR4 and less than 5inch 4mil
traces
8 001 010 1.1 -3.5 0.7 FR4 and 10inch 4mil traces
9 100 000 1.1 -6 0.6 FR4 and 15inch 4mil traces
10 010 000 1.2 0 1.2 FR4 and less than 5inch 4mil
traces
11 000 000 1.2 -3.5 0.8 FR4 and 10inch 4mil traces
12 001 000 1.2 -6 0.6 FR4 and 15inch 4mil traces
13 100 001 1.3 0 1.3 FR4 and less than 5inch 4mil
traces
14 010 001 1.3 -3.5 0.9 FR4 and 10inch 4mil traces
15 000 001 1.3 -6 0.7 FR4 and 15inch 4mil traces
16 001 001 1.3 -9 0.5 FR4 and 20inch 4mil traces
else else Not allowed
Deemphasis configuration #1 is default.
# DE0 DE1 Vp-p DEM dB internal
Vp-p
Suggested for