20. IP-DECT 400 MULTI CELL SYSTEM INSTALLATION
The IP-DECT Server 400 Multi Cell option is suitable for medium/large installations using up to 4 Base
Stations and 12 Repeaters. Up to 12 DECT handsets can be used on a multi cell system as standard, or up to
30 with an additional licence.
PART NUMBERS
Part No.
Description
Notes
ZXT548
APC 850VA UPS
1 per site
ZXT558
Matrix NENX IP50 IP-PBX (50 IP Ports)
1 per site
ZXT569
TP-Link 10 Port Ethernet Switch (8 x PoE)
1 per site
ZXT504
Spectralink IP-DECT Server 400 Multi Cell
1 per site
ZXT536
Spectralink IP-DECT Base Station
max 3 per site
ZXT508
Spectralink 4 Channel Multi Cell DECT Repeater
max 12 per site
ZXT509
Spectralink Repeater Programming Kit (USB)
1 off purchase
ZXT523
Spectralink 7202 DECT Handset & Charger
max 12 (30 with
additional licence)
ZXT524
Spectralink 7212 DECT Handset & Charger
ZCS766
BT Décor CLI Desk Telephone
1 per site
E40062
12V DC 2A Battery Backed PSU
1 per site
W03040
Spectralink DECT Repeater Plug-top PSU
Optional
W03041
Spectralink IP-DECT Server 200/400/Base Station Plug-top PSU
Optional
UPS CONNECTION
To maintain DECT operation during a mains failure the Matrix IP-PBX and Ethernet Switch must both be
powered from the battery backed output sockets on the UPS.
Note: If the Matrix IP-PBX and Ethernet Switch are plugged directly into the mains there will be no DECT
coverage during a mains failure; however, the CLI desk telephone will still operate.
DECT Handsets (12 standard)
4 Channel Multi Cell Repeaters
240V
AC
Battery Backed PSU
Matrix
IP-PBX
CLI Desk Telephone
Office Tel Line
Advent XT2 Line 1
DECT Repeaters (max 3 per Server/Base = total
12)
240V
AC
850VA
UPS
Advent XT2 Line 2
10 Port Ethernet Switch (8 x PoE)
IP-DECT Server 400
Multi Cell
IP-DECT Base Stations (max 3)
Max 6 Repeaters per PSU