icomfort Touch 7−Day Programmable Communicating Thermostat
Page 35
Optional Accessories Wiring
for use with any icomfort by Lennox system
NOTE: 24V UV LIGHT APPLICATIONS
In an icomfort by Lennox system, neither furnace
nor air handler transformer will have adequate VA to
power 24V UV light applications. An additional trans-
former for UV light applications is required.
icomfort by Lennox
FURNACE (IFC) OR
AIR HANDLER (AHC)
icomfort Touch
THERMOSTAT
DISCHARGE AIR SENSOR
(REQUIRED FOR EVEN HEAT)
(SEE DAS NOTE Page 34)
NOTE: icomfort Touch THERMOSTAT SENSES HUMID-
ITY & CONTROLS 24V H" OUTPUT (& 120V H" OUT-
PUT) TO CYCLE HUMIDIFIER BASED ON DEMAND. NO
OTHER CONTROL OR HUMIDISTAT REQUIRED.
OPTIONAL OUTDOOR AIR SENSOR FOR USE WITH HUMIDI-
FIER (IF NOT ALREADY IN THE SYSTEM FOR OTHER FUNC-
TIONS. BUILT INTO ALL icomfort by Lennox OUTDOOR
UNITS). (SEE OAS NOTE Page 34)
Maximum total
length of all con-
nections on the
RSBus is limited
to 1500ft.
Wire gauge of
RSBus wire is 18.
RSBus
Optional Accessories Wiring
for use with any icomfort by Lennox system
icomfort by Lennox
FURNACE OR AIR
HANDLER
icomfort by Lennox
FURNACE OR AIR
HANDLER
HEPA BYPASS FIL-
TER X2680 HEPA
INTERLOCK KIT
PASS INDOOR BLOWER
MOTOR COMMON WIRE
THROUGH CURRENT LOOP.
SEE HEPA INTERLOCK KIT
FOR INSTALLATION DE-
TAILS
LVCS VENTILATION
CONTROL SYSTEM
SEE LVCS VENTILATION
INSTRUCTIONS FOR DAMPER
& SENSOR WIRING
icomfort by Lennox
OUTDOOR AIR
CONDITIONING OR
HEAT PUMP UNIT
STANDARD
1 OR 2 STAGE
AC OR HP UNIT
icomfort by Lennox
FURNACE OR AIR
HANDLER
icomfort by Lennox
FURNACE OR AIR
HANDLER
(POWER COMPANY INTERRUPTION
SYSTEMS ARE WIRED SAME AS
OVERFLOW SWITCH)