EasyManua.ls Logo

Lenovo System x3550 M3 - Page 327

Lenovo System x3550 M3
564 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
See
Chapter 4 Parts listing, Lenovo System x3550 M3 Type 4254 and 7944” on page 403 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Go to the IBM support website at
http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
3038003 Firmware corrupted
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
server firmware.
2. (Trained service technician only) Replace the
system board.
3048005
Booted secondary (backup) UEFI Image Information only. The backup switch was used to boot
the secondary bank.
3048006
Booted secondary (backup) UEFI image
because of ABR
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
primary UEFI settings.
2. Turn off the server and remove it from the power
source.
3. Reconnect the server to the power source, then
turn on the server.
305000A RTC date/time is incorrect
1. Adjust the date and time settings in the Setup
utility, and then restart the server.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System board
3058001
System configuration invalid
1. Run the Setup utility, and select Save Settings.
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Reseat the following components one at a time in
the order shown, restarting the server each time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be reseated by a trained service
technician only)
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, then it
must be replaced by a trained service
technician only)
c. (Trained service technician only) System board
Chapter 3. Diagnostics 315

Table of Contents

Related product manuals