ThinkServerRAID710Adapter
ThefollowingillustrationshowstheconnectorsontheThinkServerRAID710Adapter.
Figure10.ThinkServerRAID710Adapter
1Port1
Usedtoconnectamini-SASsignalcabletothemini-SASports0-3onthebackplane.
2Port2
Usedtoconnectamini-SASsignalcabletothemini-SASprots4-7onthebackplanefor2.5-inchdrives.
3ThinkServerRAIDSuperCapacitorModuleconnector
UsedtoconnectthecableofaThinkServerRAIDSuperCapacitorModule.
Hot-swap-drivebackplane
Yourservercomeswithoneofthefollowingdrivebayandbackplaneconfigurations:
DrivebaysizeDrivebayquantityBackplanequantityDrivetype
3.5-inch41
Hot-swap,SATAorSAS
Harddiskdriveor2.5-inch
solid-statedrive
2.5-inch81
Hot-swap,SATAorSAS
Harddiskdriveorsolid-state
drive
Tolocatethebackplanes,see“Servercomponents”onpage23.
28ThinkServerRD350UserGuideandHardwareMaintenanceManual