EasyManua.ls Logo

Lenovo ThinkSystem SR650 Series - Page 75

Lenovo ThinkSystem SR650 Series
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Server model: sixteen 2.5-inch NVMe drives, two NVMe 810-4P switch adapters, two NVMe 1610-4P
switch adapters
Figure 42. Cable routing for server models with sixteen 2.5-inch NVMe drives, two NVMe 810-4P switch adapters, and
two NVMe 1610-4P switch adapters
Cable
From To
1 Power cable for front backplane 1 Power connector on front backplane
1
Backplane power connector 1 on the
system board
2 NVMe signal cable for front
backplane 1
NVMe 0 and NVMe 1 connectors on
front backplane 1
NVMe 2–3 and NVMe 0–1 connectors
on the system board
3 NVMe signal cable for front
backplane 1
NVMe 2 and NVMe 3 connectors on
front backplane 1
C0, C1, C2, and C3 connectors on
the NVMe 1610-4P switch adapter
installed in PCIe slot 6
4 Power cable for front backplane 2 Power connector on front backplane
2
Backplane power connector 2 on the
system board
5 NVMe signal cable for front
backplane 2
NVMe 0 connector on front
backplane 2
C0 and C1 connector on the NVMe
810-4P switch adapter installed in
PCIe slot 4
6 NVMe signal cable for front
backplane 2
NVMe 1 connector on front
backplane 2
C0 and C1 connector on the NVMe
810-4P switch adapter installed in
RAID adapter slot on the system
board
7 NVMe signal cable for front
backplane 2
NVMe 2 and NVMe 3 connectors on
front backplane 2
C0, C1, C2, and C3 connectors on
the NVMe 1610-4P switch adapter
installed in PCIe slot 1
Chapter 2. Server components 71

Table of Contents

Related product manuals