Safety instructions
Residual hazards
2
75
EDK82MV752 DE/EN/FR 7.2
ƒ If you use the function "flying restart circuit" (C0142 = 2, 3) for machines with a low
moment of inertia and low friction:
After controller enable at standstill, the motor can start for a short time or change
its direction of rotation for a short time.
ƒ The motec heatsink has an operating temperature > 60 °C:
Direct skin contact with the heatsink results in burns.
Device protection
ƒ Frequent switching of the supply voltage (e.g. inching mode via mains contactor)
can overload and destroy the input current limitation of the controller:
Wait for at least 3 minutes between two starting operations.
ƒ Only switch contactors in the motor cable when the controller is inhibited.
Otherwise ...
monitoring functions of the controller can be activated.
the controller can be destroyed under unfavourable operating conditions.
Motor protection
ƒ For some controller settings, the connected motor may overheat (e.g. when
operating the DC injection brake or a self−ventilated motor at low speed for longer
periods).
Using an overcurrent relay or a temperature monitoring device provides a large
degree of protection against overload.
We recommend to use PTC thermistors or thermal contacts for motor temperature
monitoring. (Lenze three−phase AC motors are equipped with thermal contacts
(NC contacts) as standard)
PTC thermistors or thermal contacts can be connected to the controller.
Protection of the machine/system
ƒ Drives can attain dangerous overspeeds (e.g. setting of high output frequencies with
motors and machines not qualified for this purpose).
The controllers do not offer any protection against these operating conditions. Use
additional components for this purpose.