Mechanical installation
Motor mounting
Motor connection
4
89
EDK82MV752 DE/EN/FR 7.2
4.3.3 Motor connection
Danger!
ƒ All control terminals only have basic insulation (single isolating distance)
after connecting a PTC thermistor or a thermal contact.
ƒ Protection against accidental contact in case of a defective isolating
distance is only guaranteed through external measures, e. g. double
insulation.
8200mot408
91
8200mot408
X2/PE2 Do not use the terminal
X2/BR1, X2/BR2 Brake resistor terminals
(For information on operation with brake resistor: see operating instructions)
X2/T1, X2/T2 Terminals of motor temperature monitoring with PTC thermistor (PTC) or thermal contact
Activate motor temperature monitoring with C0119 (e.g. C0119 = 1)!