7
Commissioning
The most important codes for commissioning
EDK82EV113 DE/EN/FR 8.1
L
144
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0007
uSEr
Fixed
configuration of
digital inputs
Change under C0007 will be copied
to the corresponding subcode of
C0410. Free configuration under
C0410 sets C0007 = 255!
0
E4 E3 E2 E1
l CW/CCW = CW rotation/CCW
rotation
l DCB = DC injection brake
l QSP = Quick stop
l PAR = Parameter set changeover
(PAR1 ó PAR2)
PAR1 = LOW, PAR2 = HIGH
The terminal must be assigned
to the function "PAR" in PAR1
and PAR2.
Configurations with "PAR" are
only allowed if C0988 = 0
l TRIP set = external fault
0
CW/CCW DCB JOG2/3 JOG1/3
1
CW/CCW PAR JOG2/3 JOG1/3
2
CW/CCW QSP JOG2/3 JOG1/3
3
CW/CCW PAR DCB JOG1/3
4
CW/CCW QSP PAR JOG1/3
5
CW/CCW DCB TRIP set JOG1/3
6
CW/CCW PAR TRIP set JOG1/3
7
CW/CCW PAR DCB TRIP set
8
CW/CCW QSP PAR TRIP set
9
CW/CCW QSP TRIP set JOG1/3
10
CW/CCW TRIP set UP DOWN
C0007
uSEr
(cont.)
E4 E3 E2 E1
l JOG1/3, JOG2/3 = Selection of
fixed setpoints
Activate JOG1:
JOG1/3 = HIGH; JOG2/3 = LOW
Activate JOG2:
JOG1/3 = LOW; JOG2/3 = HIGH
Activate JOG3:
JOG1/3 = HIGH; JOG2/3 = HIGH
l UP/DOWN = motor potentiometer
functions
11
CW/CCW DCB UP DOWN
12
CW/CCW PAR UP DOWN
13
CW/CCW QSP UP DOWN
14
CCW/QSP CW/QSP DCB JOG1/3
15
CCW/QSP CW/QSP PAR JOG1/3
16
CCW/QSP CW/QSP JOG2/3 JOG1/3
17
CCW/QSP CW/QSP PAR DCB
18
CCW/QSP CW/QSP PAR TRIP set
19
CCW/QSP CW/QSP DCB TRIP set